Regulated D.C Power Supply
Regulated D.C Power Supply for Accurate DC Voltage
A regulated DC power supply unit generates a continuously variable DC output voltage while maintaining excellent load and line control. The regulated d.c power supply is also known as linear regulated dc power supply. A digital meter displays the voltage output. A delayed blow fuse at the input and overload protection at the output provide internal protection.
We are one of the top leading Regulated D.C power Supply Manufacturers in India offering DC power supply that maintains a consistent DC voltage regardless of AC input variations in load resistance levels. Additionally, all products are produced with high precision and tested before being supplied to ensure their longevity.
Various Models We Have
Our Models
DC REGULATED POWER SUPPLY 0 - 32V
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 1A CES - 504
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 2A CES - 503
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 5A CES - 502
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUTVOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUTCURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 10A CES - 501
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 20A CES - 500
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 30A CES - 505
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 64V
DC REGULATED POWER SUPPLY
0 - 64V /0-1A CES - 506
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 2A CES - 507
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 5A CES - 508
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 10A CES - 509
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 20A CES - 509-2
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 30A CES - 509-3
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 128V
DC REGULATED POWER SUPPLY
0 - 128V /0 - 1A CES - 510
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 128V /0 - 2A CES - 511
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 128V / 5A CES - 512
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 128V / 0 - 10A CES - 513
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 300V
DC REGULATED POWER SUPPLY
0 - 300V / 0 - 5A CES - 715
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 300V / 0 - 2A CES - 716
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
HIGH VOLTAGE DC REGULATED POWER SUPPLY
0 - 300V/0 - 1A CES - 717
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Know More
Get Regulated D.C Power Supply From Reliable Suppliers!
Crown Electronics Systems is a reliable regulated d.c power supply manufacturer, supplier, and exporter. Our variable dc regulated power supply is widely used in a wide range of industries and educational institutions. Moreover, the finest quality raw materials are used in its production, and it is made utilizing advanced technology.
The production process is carried out under the supervision of specialists, ensuring that our Regulated D.C power Supply is free of flaws. We believe that being one of the most reliable Regulated D.C power Supply Suppliers in India, offering high-quality products is our responsibility. For more, you may contact us!
Our Models
Various Applications & Features Of
Regulated D.C Power Supply
Most popular
Features of Regulated D.C Power Supply
- High efficiency
- More dependable
- Simpler circuit
- Faster reaction
- Inexpensive
- Low noise level
- Bench power supplies
Most popular
Applications of Regulated D.C Power Supply
- Testing circuits
- Automatic control systems, etc.
Need assistance?
If you have any queries related to our products or want assistance with any of our products, kindly let us know!
Or call us now
(+91)-7838002712
Contact us on the given number to buy any of our products.