Dual Output DC Regulated Power Supply manufactured by Crown Electronics Systems are Constant voltage and current supplies have strong regulation for variations in load and line voltage. The supply is safeguarded against overload and short circuits. Any value between 0 and the maximum can be set for the output current. We are one of the renowned Dual Output DC Regulated Power Supply Manufacturers in India.
This product of ours can work in constant voltage and constant current modes. Any voltage or current within the range can be set from CV to CC mode. Separate front panel meters are provided to monitor the variable output portions' output voltage and load current. The variable outputs' output voltage and current limit parameters can be changed manually using the front panel controls.
Various Models We Have
Our Models
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±32V
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±32V/0-1A CES - 603
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ±0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% + 1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±32V/0-2A CES - 602
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ± 0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : ± 0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% + 1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±32V/0-5A CES - 601
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ± 0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% ±1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - +32V / 10A CES - 600
INPUT VOLTAGE : 230V ±10% AC 50 Hz
LOAD REGULATIONCV : ±0.05 % ±3mV From no load to full load
LOAD REGULATIONCC : ±0.05% ±1mA From no load to full load
LINE REGULATIONCV : ±0.01 % ±3mV for +10% variation input voltage
LINE REGULATIONCC : ±0.01% ±1mA for ±10% variation input voltage
OPERATINGMODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FORCV & CC Operating Mode
ACCURACY : ±1% ±1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±32V/20A CES - 600-2
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ± 0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% ±1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±32V/30A CES - 600-3
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC :±0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% ±1 Digit
PROTECTION : Against short circuit & over load
Our Models
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±64V
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±64V / 0 - 1A CES - 604
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ±0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% + 1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±64V / 0 - 2A CES - 605
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ± 0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ± 0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% +1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±64V / 0 - 5A CES - 606
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ±0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ± 0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% +1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±64V / 0 - 10A CES - 607
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ±0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ± 0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 1 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% + 1 Digit
PROTECTION : Against short circuit & over load
Our Models
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±128V
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±128V/0 - 1A CES - 608
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ±0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : 2 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : + 1% + 1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±128V/0 - 2A CES - 609
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : ±0.05% ±1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : 2 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% ±1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±128V/0 - 5A CES - 610
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for ±10% variation input voltage
LINE REGULATION CC : ±0.01% ±1mA for ±10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : 2 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : ±1% + 1 Digit
PROTECTION : Against short circuit & over load
Our Models
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±300V
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±300V/0 - 1A CES - 611
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 3 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : + 1% + 1 Digit
PROTECTION : Against short circuit & over load
DUAL OUTPUT DC REGULATED POWER SUPPLY 0 - ±300V/0 - 2A CES - 612
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
OPERATING MODE : Independent & Tracking mode
RIPPLE : Less than 3 mV
METER : Four Digital meters to monitor the output voltage & current voltage & current of A & B Supply
INDICATION : LED FOR CV & CC Operating Mode
ACCURACY : + 1% + 1 Digit
PROTECTION : Against short circuit & over load
Know More
Excellent Quality Dual Output DC Regulated Power Supply at a Reasonable Price
As one of the prominent Dual Output DC Regulated Power Supply Suppliers in India, we manufacture and export high-quality Dual Output DC Regulated Power Supply. This power supply device is a constant voltage and current limit type supply that produces a high regulation power for load and line voltage variation.
We design this Dual Output DC Regulated Supply under the supervision of our professional specialists, using superior quality materials in compliance with industry quality standards. In addition, the Dual Output DC Regulated Power Supply, Ic Regulated Dual Display Power Supply, Dual Output DC Regulated Power Supply 0-32V/ 0-10A, and Dual Output DC Regulated Power Supply 0-64V/0-10A all are reasonably priced. Contact us for more!
Our Models
Various Applications & Features Of
Dual Output DC Regulated Power Supply
Most popular
Features of Dual Output DC Regulated Power Supply
- Protection against short circuit
- Optimum performance
- Long life span
Most popular
Applications of Dual Output DC Regulated Power Supply
- Audio amplifiers and preamplifiers
- Analog signal processing circuits
- Lab equipment and instrumentation
- Industrial control systems
- Robotics and automation systems
Need assistance?
If you have any queries related to our products or want assistance with any of our products, kindly let us know!
Or call us now
(+91)-7838002712