DC Regulated Power Supply
DC Regulated Power Supply: To Avoid Fluctuation
By changing uncontrolled alternating current (AC) to constant direct current (DC), a regulated power supply, also commonly referred to as a linear power supply, guarantees that the output current will not fluctuate regardless of changes in the input. Crown Electronics Systems produced DC Regulated Power Supply that provides good regulation for load and line voltage variation and are constant voltage & current constant type supplies.
The supply is short-circuited and overload-protected. The output current can be set to any value between zero and maximum. We are one of the reliable DC Regulated Power Supply Manufacturers in India that provides customers with high-quality products.
Various Models We Have
Our Models
DC REGULATED POWER SUPPLY 0 - 32V
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 1A CES - 504
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 2A CES - 503
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 5A CES - 502
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUTVOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUTCURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 10A CES - 501
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 20A CES - 500
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 32V / 0 - 30A CES - 505
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 64V
DC REGULATED POWER SUPPLY
0 - 64V /0-1A CES - 506
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 2A CES - 507
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 5A CES - 508
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 10A CES - 509
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 20A CES - 509-2
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 64V /0 - 30A CES - 509-3
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 128V
DC REGULATED POWER SUPPLY
0 - 128V /0 - 1A CES - 510
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 128V /0 - 2A CES - 511
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 128V / 5A CES - 512
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 128V / 0 - 10A CES - 513
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 300V
DC REGULATED POWER SUPPLY
0 - 300V / 0 - 5A CES - 715
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC REGULATED POWER SUPPLY
0 - 300V / 0 - 2A CES - 716
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
HIGH VOLTAGE DC REGULATED POWER SUPPLY
0 - 300V/0 - 1A CES - 717
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Know More
DC Regulated Power Supply: We Are the Top Supplier!
A dependable, DC-regulated power supply offered by us, the leading DC Regulated Power Supply Suppliers in India is ideal for lab work, research, R&D, and industrial applications. Its linear architecture allows for silent, stable operation with little ripple and delay during conversion, transformation, and adjustment.
We, the dc regulated power supply manufacturers India, provide excellent quality equipment that is used extensively in production line testing, electrical maintenance, aging products, battery charging, laboratories, scientific research and education, and a variety of other applications. If you are looking for a top-quality dc regulated power supply India, you may contact us.
Applications & Features
Various Applications & Features Of
DC Regulated Power Supply
Most popular
Features of DC Regulated Power Supply
- AC Input Supply Range (Universal)
- The output voltage is continuously adjustable via coarse and fine settings
- Short circuit and overload protection
- Dual output with distinct coarse and fine models
- High-quality display
Most popular
Applications of DC Regulated Power Supply
- Testing Circuits
- Testing mobile phone chargers
- Regulated power supplies in different appliances
- Various oscillators & amplifiers
- Audiovisual applications
Need assistance?
If you have any queries related to our products or want assistance with any of our products, kindly let us know!
Or call us now
(+91)-7838002712
Contact us on the given number to buy any of our products.