DC Power Supply

DC Power Supply at Crown Electronics Systems
A power supply must deliver consistent and exact voltage and current with little noise to any type of load: resistive, inductive, low impedance, high impedance, steady-state, or variable. The power supply is the most important component of any industry. DC power supply provides a controlled DC output to power a component, module, or device.
Crown Electronics Systems manufactures on a wide scale dependable, most precise, completely specified, certified, and efficient power supply equipment with powerful output protection and fault detection capabilities. We are one of the prominent DC Power Supply Manufacturers in India and our DC Power Supplies are manufactured for a variety of applications with varying Voltage and Current parameters.
Various Models We Have
Our Models
DC REGULATED POWER SUPPLY 0 - 32V

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 1A CES - 504
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 2A CES - 503
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 5A CES - 502
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUTVOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUTCURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 10A CES - 501
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 20A CES - 500
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 30A CES - 505
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 64V

DC REGULATED POWER SUPPLY
0 - 64V /0-1A CES - 506
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 64V /0 - 2A CES - 507
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 64V /0 - 5A CES - 508
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 64V /0 - 10A CES - 509
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 64V /0 - 20A CES - 509-2
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 64V /0 - 30A CES - 509-3
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 128V

DC REGULATED POWER SUPPLY
0 - 128V /0 - 1A CES - 510
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 128V /0 - 2A CES - 511
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 128V / 5A CES - 512
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 128V / 0 - 10A CES - 513
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Our Models
DC REGULATED POWER SUPPLY 0 - 300V

DC REGULATED POWER SUPPLY
0 - 300V / 0 - 5A CES - 715
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

DC REGULATED POWER SUPPLY
0 - 300V / 0 - 2A CES - 716
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

HIGH VOLTAGE DC REGULATED POWER SUPPLY
0 - 300V/0 - 1A CES - 717
INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
Know More
Top Dc Power Supply With Excellent Performance And Dependability
Crown Electronics Systems provides a wide range of DC power supply, as well as a variety of voltage and current ranges, from tiny to large capacitance. Because all models like Dual Output Regulated Dc Power Supply, support arbitrary and variable voltage and current settings, they are appropriate for a wide range of applications ranging from simple stabilization to integration, testing, and evaluation.

We are the most trusted DC Power Supply Suppliers in India, providing power supply with a smooth and steady output voltage at 100% conversion efficiency, independent of changes in the voltage, load current, or ambient temperature,
Our Models
Various Applications & Features Of
DC Power Supply
Most popular
Features of DC Power Supply
- Low-temperature fluctuation
- Rapid transient reaction
- Low ripple noise voltage
- Several safety functions
Most popular
Applications of DC Power Supply
- Mobile phones
- IoT gadgets
- Medical items
- Remote industrial sensors
Need assistance?
If you have any queries related to our products or want assistance with any of our products, kindly let us know!
Or call us now
(+91)-7838002712
Contact us on the given number to buy any of our products.